여전히 NMI 관련한건 모르겠다 ㅠ.ㅠ
일단 용어 부터 조사를 해보자면 아래와 같은 약어들이 보인다.



----

PERR(Parity ERRor)
[링크 : http://ip.com/IPCOM/000010806]

IERR(Internal ERRor)
SERR(Signal ERRor)
[링크 : http://ibmss.tistory.com/entry/컴퓨터오류-IERR-과-SERR-오류-발생-의미]

FRB(Fault Resilient Booting)
[링크 : http://www.andovercg.com/datasheets/intel-SE7501WV2-motherboard-specs.pdf]

Table 13. System Management Submenu Options

Feature

Option

Description

Firmware SMIs Disabled
Enabled
Enables SMI generation.
System Event Logging Disabled
Enabled
Enables logging of critical events.
Clear Event Log Disabled
Enabled
Clears the System Event Log. This feature is reset to Disabled each time the system boots.
Memory Scrubbing Disabled
Enabled
Enables the system chip set to automatically detect and correct single-bit memory errors.
AERR Enable Disabled
Enabled
Enables the AERR signal.
Assert NMI on BERR Disabled
Enabled
Enables the BERR signal to be reported as a critical event via NMI. The Firmware SMIs option must also be enabled.
Assert NMI on PERR Disabled
Enabled
Enables the PERR signal to be reported as a critical event via NMI. The Assert NMI on SERR option must also be enabled.
Assert NMI on SERR Disabled
Enabled
Enables the SERR signal to be reported as a critical event via NMI.
Enable Host Bus Error Disabled
Enabled
Enables reporting of single-bit and multi-bit errors.
FPC Error Check Disabled
Enabled
If enabled, the BIOS verifies that it can connect with the front panel controller (control panel board) during system boot.
HSC Error Check Disabled
Enabled
If enabled, the BIOS verifies that it can connect with the Hot Swap Controller during system boot.
Server Management Information Highlighting and pressing <Enter> selects the Server Management Information submenu.

[링크 : http://support.dell.com/support/edocs/systems/sdiam/en/sm/setup.htm

'하드웨어 > Server Case & board' 카테고리의 다른 글

EFI boot Manager  (0) 2011.07.30
DDR-266과 DDR-333에 따른 메모리 사용용량 차이  (0) 2011.07.27
SCSI - Ultra320 68pin  (0) 2011.07.20
아오 ㅋㅋㅋ 이렇게 빠질줄이야  (0) 2011.07.20
MROMB / ROMB  (0) 2011.07.09
Posted by 구차니

분해한김에 하드 찰칵!

Ultra 320 SCSI / 68pin 하드
점퍼 셋팅은 오른쪽과 같이 ID0~3 까지 3bit/8개 까지 사용이 가능한 녀석인데..
음... SCSI 컨트롤러는 0~15까지인데 멀까....나?


까매서 잘 안보이지만.. 아무튼 68pin Male connector
저 점퍼는 용도 불명 -_- (설마 JTAG은 아니겠지?) 


위의 점퍼셋팅 사진을 참고하여 보자면
ID0에 셋팅(즉 ID는 1)
START CMD
TERM PWR EN 


ID 셋팅없음(즉 ID는 0)
START CMD
TERM PWR EN 


68pin Male Connector


케이블의 끝에 달린 Terminator
이녀석 때문에 아까 위에서 TERM PWR EN이 설정된건가?


케이블 자체도 꼬여있고 아무튼 반들반들한게 비싸보인다



---
[링크 : http://day55.com/bbs/view.php?...no=1056

START CMD는 Motor start mode 라고해서, 전원 인가시 모터를 미리 회전시키는지에 대한 설정이라고 하고
TERM PWR EN은 Terminator Power Enable 인듯 한데, 터미네이터에 전원을 공급할지 여부를 결정한다.
터미네이터가 단순 저항인줄 알았는데.. 전원도 공급을 해주어야 하는건가...
아무튼 터미네이터에 전원을 인가하지 않으면 아마도 터미네이터를 인식하지 못해
하드 속도가 느려지는(터미네이터를 찾으려다가 timeout을 기다리는 듯) 문제가 있으니 주의해야 할 듯.


[링크 : http://www3.toshiba.co.jp/storage/english/techinfo/img/AL_jumper_EN.pdf ]

 

'하드웨어 > Server Case & board' 카테고리의 다른 글

DDR-266과 DDR-333에 따른 메모리 사용용량 차이  (0) 2011.07.27
NMI 관련 CMOS(BIOS) 설정 페이지  (0) 2011.07.20
아오 ㅋㅋㅋ 이렇게 빠질줄이야  (0) 2011.07.20
MROMB / ROMB  (0) 2011.07.09
SCSI  (0) 2011.07.03
Posted by 구차니
서버 케이스 열쇠가 없어서 하드를 빼지도 못하고 고심하면서 한달을 썩혔는데
혹시나 해서 해봤더니.. 헉 -_- 이렇게 허무하게 빠질줄이야!

오른쪽 걸쇠부분을 당겨서 빼고 오른쪽으로 빼니 아래와 같이 슝~


열쇠가 아래의 부분에 걸리는데 오른쪽으로 약간의 공간만 확보해주면 파괴하지 않고 뺼수 있다!


쑥~ 하고 빼버린 전면 커버 -_-


하드 케이스. 덕분에 팬에도 기름도 칠해주고~ 하드 사진도 찍어주고!



결론 : 아놔 한달 -_- 그냥 공으로 날렸자너!

'하드웨어 > Server Case & board' 카테고리의 다른 글

NMI 관련 CMOS(BIOS) 설정 페이지  (0) 2011.07.20
SCSI - Ultra320 68pin  (0) 2011.07.20
MROMB / ROMB  (0) 2011.07.09
SCSI  (0) 2011.07.03
ROMB  (0) 2011.07.03
Posted by 구차니
MROMB - Modular ROMB
ROMB - Raid on MainBoard

ROMB는 메인보드에 Raid 컨트롤러와 SCSI 컨트롤러 등이 내장된 형태이고

MROMB는 메인보드에는 SCSI 컨트롤러가 장착되고 별도의 카드 타입의 RAID 컨트롤러가 장착되는 형태이다.
ZCR(Zero Channel RAID) 라고도 불리우며 
MROMB 에는 SCSI 채널용 슬롯이 없는것이 특징(?) 이다.

즉, ZCR의 경우 메인보드에 SCSI 컨트롤러가 장착되고
MROMB는 RAID만 순수하게 작동시키고 메인보드의 SCSI 컨트롤러는 제어하게 된다. 

HBA는 Host Based Adaptor로 일반적인 RAID+SCSI 컨트롤러를 지칭한다.


MROMB는 SCSI 컨트롤러는 메인보드에/ MROMB는 RAID 카드에만 장착된다.
즉, SCSI는 필요하지만 RAID까지 사용할 필요가 없는 사람에게는 유용한 선택이다. 


RAID 컨트롤러는 PCI를 통해서 SCSI 컨트롤러와 연결되어 제어하게 된다.


[링크 : http://www.intel.com/design/network/papers/25157501.pdf
[링크 : http://www.certforumz.com/Forum/index.php?topic=69.0]
[링크 : http://www.intel.com/design/support/faq/io_processors/raidios.htm

--- 2011.07.10 추가


[링크 : http://reviews.cnet.com/i-o-cards/icp-vortex-gdt8500rz-storage/1707-3019_7-32550701.html

'하드웨어 > Server Case & board' 카테고리의 다른 글

SCSI - Ultra320 68pin  (0) 2011.07.20
아오 ㅋㅋㅋ 이렇게 빠질줄이야  (0) 2011.07.20
SCSI  (0) 2011.07.03
ROMB  (0) 2011.07.03
Intel Integrated Mirroring / Integrated Striping RAID for Intel Server Boards SE7520BD2  (0) 2011.07.03
Posted by 구차니
SCSI는 daisy chain 방식으로 구성된다.
그런 이유로 리본케이블 하나로 연결하면 되니 RAID도 구성이 용이했던것 같다.
(아무래도 IDE는 한 케이블당 2개 최대 Pri/Sec/Ter 3개의 커넥터가 존재하여 총 6개가 한계)
구형의 장비라고 해도 하드만 7개 장착이 가능한 SCSI가 아무래도 케이블도 깔끔하고..

지금은 4bit ID로 총 16개의 장비중 1개는 Host adaptor가 사용하는데
과거에 7번(0~7번 가장 마지막 번호)를 host adaptor로 사용하던 관습으로 인해
지금도 7번이 호스트로 de facto로 쓰이고 있고,
0은 HDD
2는 FDD
3은 ODD 로 주로 사용을 한다고 한다.

아무튼 16개를 어떻게 아이디를 주나 고심을 했더니 4bit이고 즉, 점퍼는 4개면 충분하다.
(2^4=16, 즉, 4개의 점퍼면 4비트로 충분히 나타낼수 있음)

[링크 : http://blog.naver.com/jbw535/60123695291

[링크 : http://en.wikipedia.org/wiki/SCSI]
[링크 : http://www.pcguide.com/ref/hdd/if/scsi/confIDs-c.html
Posted by 구차니
100% 확신은 못하지만 ROMB는 아마도..
RAID on Main Board의 약자인듯
[링크 : http://www.webopedia.com/TERM/R/ROMB.html]

Ultra320 SCSI
SE7520BD2V:
 One Ultra320/LVD channel via either the LSI Logic* 53C1020 or  LSI Logic 53C1020A SCSI controller, supporting RAID 0 and 1, and support for modular ROMB (Intel® RAID Controller SRCZCRX)

SE7520BD2SCSI:
 Two Ultra320/LVD channels via the LSI Logic 53C1030 SCSI controller and connected via  two internal 68-pin-wide connectors; maximum data transfer 320 MB/sec on each Ultra320/LVD channel, supporting RAID 0 and 1, and support for modular ROMB (Intel RAID Controller SRCZCRX)

아무튼.. Onboard된 RAID 컨트롤러 칩이 있더라도, 연산은 CPU로 돌리는 Software RAID가 대부분인듯 하다.
(괜히 카드 타입 RAID가 비싼게 아니었군) 


[링크 : http://promise.com/storage/raid_category.aspx?region=ko-KR&m=242&rsn=39&statistic=ROMB]

'하드웨어 > Server Case & board' 카테고리의 다른 글

MROMB / ROMB  (0) 2011.07.09
SCSI  (0) 2011.07.03
Intel Integrated Mirroring / Integrated Striping RAID for Intel Server Boards SE7520BD2  (0) 2011.07.03
Intel Server Board SE7520BD2V  (0) 2011.07.02
Intel Entry Server Chassis  (0) 2011.06.25
Posted by 구차니
내용을 읽다가 도대체 이건 쓰라고 해놓은건지 쓰지말란건지 분간이 안되는 상황 -_-
SCSI 컨트롤러에 내장된 RAID 가 RAID L0 / L1만 지원하고 L5 이런건 지원하지도 않고
내장 RAID는 CPU를 사용하므로 cpu에 부하가 걸리면 IO가 떨어진다는 협박문구라니 -ㅁ-! 

결론 : 그냥 RAID 1(mirroring) 으로 쓰는것 정도 외에는 별로인듯?

1. Integrated RAID Overview 
The integrated RAID solution provides cost benefits for the server or workstation market where 
the extra performance, storage capacity, and/or redundancy of a RAID configuration are 
required. The two components of integrated RAID are: 
 
ƒ  Integrated Mirroring (IM) provides features of RAID 1 
ƒ  Integrated Striping (IS) provides features of RAID 0

By simplifying the IM and IS configuration options and by providing firmware support in its host 
adapters, integrated RAID can offer the integrated RAID solution at a lower cost than a full-blown RAID implementation. 

This document provides a reference to expedite the configuration of integrated RAID.  
Notes: 

- Integrated RAID offers advanced features including I/O performance with additional data 
security; however, there are several considerations of which to be aware.  
- Only one RAID configuration (logical drive) is allowed. 
- Integrated RAID may take an extended period of time to complete the initialization after 
the RAID setup. The amount of time required depends whether the initialization is 
completed within the BIOS-based utility or completed with the operating system-based 
utility. The amount of time required also depends on the complexity of the configuration 
and capability of the system being configured. 
- Unlike a hardware controller, integrated RAID consumes system resources such as CPU 
cycles and system memory to handle I/O requests; in a situation where the CPU is 
heavily loaded, the I/O performance may drop significantly. 

2. Integrated RAID Implementation Guidelines 
2.1 Integrated Mirroring
 
Integrated Mirroring (IM) provides data protection for the system volume. The purpose is to 
safeguard critical information, such as the operating system.  
IM can be set up with two hard disk drives to maintain high performance, as well as data 
availability and fault tolerance. If one disk drive fails, the hot swap drive mechanism allows the 
system to maintain operation while the failed disk drive can be replaced. In addition, the hot 
spare capability enables the system to automatically replace the defective drive with a standby 
disk. 
IM requires extra time synchronization in BIOS mode as compared to the synchronization time 
in operating system mode. In BIOS mode (<Ctrl>+<C>), 1 hour for each 5 gigabytes of hard 
drive capacity is typically required to complete initializing the mirror. For example, for two 100 
gigabyte drives configured in a RAID 1 mirroring, 18-20 hours should be allowed for the 
initialization to complete.  
The IM firmware uses queue tagged I/Os to allow SCSI I/Os to continue on the IM volume while 
the volume is re-synchronized in the background. The host driver may optionally suspend the 
resynchronization operation while performing domain validation or while configuring Ultra320 
SCSI expanders.  
 
2.2 Integrated Striping 
Integrated Striping (IS) is available for applications that require faster I/O performance and 
higher storage capacity for non critical data. With this option there is no drive failover. Failure of 
a drive results in a loss of all data on the drives holding the data stripe. By reading and writing 
data concurrently across several disks, IS offers excellent performance as compared to a single 
physical disk. However, the risk of data loss increases because a single disk failure will cause 
the loss of the entire logical drive. 
The IS configuration is available only for new installations. Migration of data with existing disks 
is not supported.  

---- 2011.07.27 추가

아무튼, 일반 하드에서 RAID 0 로 변경은 지원하지 않으며
RAID 1 로 변경은 무지 오래 걸린다고 한다.


[링크 : ftp://download.intel.com/support/motherboards/server/sb/raid_im_is_guide_13.pdf]

'하드웨어 > Server Case & board' 카테고리의 다른 글

SCSI  (0) 2011.07.03
ROMB  (0) 2011.07.03
Intel Server Board SE7520BD2V  (0) 2011.07.02
Intel Entry Server Chassis  (0) 2011.06.25
지름신 신고  (4) 2011.06.24
Posted by 구차니

요렇게 생겨먹은 녀석임
 




이번에 구매한 xeon 서버의 보드인데
보드사양이 조금씩 달라서 실제로 SE7520BD2 인지 확신은 못한다.
PCI-Ex 라던가 미묘하게 다르다 보니 -_-
아무튼 보드에 적힌 모델명이랑 전혀 다른 녀석이 나오는 희한한 케이스 OTL

특이사항으로는 Intel GbE와 Marvell GbE 2개가 장착되어 있는데
Intel 쪽은 Server Adaptor는 아닌듯 하고 Marvell 쪽을 마스터로 하여 Teaming이 가능한지는 찾아봐야 한다.
(물론 NIC 드라이버 번호 상으로는 Intel 이 우선적으로 잡히는 듯)

드라이버는 아래 링크에서 받으면 된다
[링크 : http://downloadcenter.intel.com/...Server+Board+SE7520BD2]

아래는 제품설명 페이지
[링크 : http://www.intel.com/.../se7520bd2/feature/index.htm

'하드웨어 > Server Case & board' 카테고리의 다른 글

SCSI  (0) 2011.07.03
ROMB  (0) 2011.07.03
Intel Integrated Mirroring / Integrated Striping RAID for Intel Server Boards SE7520BD2  (0) 2011.07.03
Intel Entry Server Chassis  (0) 2011.06.25
지름신 신고  (4) 2011.06.24
Posted by 구차니
정식서버/정식서버 케이스다 보니 신기한 용어 속출 -_-

SSI-EEB는 Xeon 플랫폼을 위한 케이스를 지칭한다.
NMI는 스위치 형태로 존재한다.

EEB : Entry E-Bay  
NMI : Non Maskable Interrupt 
SSI : Server System Infrastructure

 
[링크 : http://download.intel.com/support/motherboards/server/chassis/sc5275-e/sb/sc5275_tps_ver_12.pdf]
 
[링크 : http://en.wikipedia.org/wiki/SSI_CEB]
[링크 : http://en.wikipedia.org/wiki/Non-maskable_interrupt]


특이점(?) 은 NMI 용 스위치가 전면에 있다는거(아마도 하드웨어 문제라고 강제로 설정하는 버튼인듯)
그리고 일반적인 PC와는 다르게 랜이나 하드등의 LED가 전면에 보이고
이러한 것에 대한 케이블이 헤더가 아닌 리본 케이블로 연결이 된다는 점이다.


 
 


[링크 : http://www.intel.com/.../sc5275-e/.../167368.htm#additional]

'하드웨어 > Server Case & board' 카테고리의 다른 글

SCSI  (0) 2011.07.03
ROMB  (0) 2011.07.03
Intel Integrated Mirroring / Integrated Striping RAID for Intel Server Boards SE7520BD2  (0) 2011.07.03
Intel Server Board SE7520BD2V  (0) 2011.07.02
지름신 신고  (4) 2011.06.24
Posted by 구차니
지름신 no.1 도착!
Xeon 3.0Ghz x 2 워크스테이션


CPU는 일단 Nocona(조사해보니 펜티엄4 프레스캇의 Xeon 버전이라고 하던디)
HT를 지원하는듯 하고(작업관리자에서 4개 뜬다)
64bit도 지원인가? (EM64T가 64 비트 맞나?)


메모리는 DDR1에 ECC/REG/unbufferd PC2700


등급이 낮은건 내장 그래픽 때문임 -_-
아무튼, 메인보드에 원래 랜카드가 2개인데 추가로 예전에 구매했던
Intel Pro/1000 Dual Server Ethernet 장착!
그런 이유로 랜카드 4개의 위ㅋ엄ㅋ



하드는 SCSI Ultra320 147GB 인데
솔찍히 다른 하드랑 비교를 안해봐서 빠른건지 느린건지 모르겠다.
아무튼 덕분에 SCSI 장비도 만져보고 신기해 하는중 -ㅁ-!
Fujitsu (MAT3147NP) 147 GB SCSI Ultra320 Hard Drive
Price Range:  $131.00 to $135.00

Fujitsu's latest generation of Enterprise SCSI Hard Disk Drives offer capacities of up to 300GB in a 1-inch high, 3.5-inch form... Read More
Fujitsu's latest generation of Enterprise SCSI Hard Disk Drives offer capacities of up to 300GB in a 1-inch high, 3.5-inch form factor. The MAT SCSI series is the latest generation Hard Disk products from Fujitsu offering low profile, high speed and high capacity to high performance enterprise computing applications. The MAT (NP) series comes with a 68-pin interface connector, and spindle speed of 10K RPM. Areal density has doubled and internal drive transfer rates have been increased by 22% to 132 MB/s when compared to the previous MAP series. The drive is also equipped with an 8MB multi-segmented data buffer combined with a 32-bit wide internal data path for faster data access. The MAT NC/NP series supports the Ultra 320 SCSI (320MB/s) interface, which offers new performance and reliability enhancing features such as data packet protocol, quick arbitration and selection, and signal pre-compensation

[링크 : http://www.dealtime.com/147GB-10000-RPM-U320-SCSL-HDD-68-PIN-SCA2-LVD/info?sb=1]

최대 80MB 정도면 GbE 하나 대역폭 겨우 버티는 정도..
RAID로 묶어야지 듀얼 채널을 묶어서 버텨줄듯


지름신 no.2 배송중!
3Ware 9500 SATA 4Channel RAID card




서버 하나 지름으로서 죽어가던(?) PCI-X 하나와 지를 PCI-X 의 용도가 확정되었다!
그나저나.. 소리가 시끄러운건.. 서버(혹은 워크스테이션)의 종특인듯..

'하드웨어 > Server Case & board' 카테고리의 다른 글

SCSI  (0) 2011.07.03
ROMB  (0) 2011.07.03
Intel Integrated Mirroring / Integrated Striping RAID for Intel Server Boards SE7520BD2  (0) 2011.07.03
Intel Server Board SE7520BD2V  (0) 2011.07.02
Intel Entry Server Chassis  (0) 2011.06.25
Posted by 구차니