\CONFIGURATION OVERVIEW
After power-on or reset, the AD4111 default configuration is as follows:
• Channel configuration: Channel 0 is enabled, the VIN0 and VIN1 pair is selected as the input. Setup 0 is selected.
• Setup configuration: the analog input buffers are disabled and the reference input buffers are also disabled. The REF± pins
are selected as the reference source. Note that for this setup, the default channel does not operate correctly
because the input buffers need to be enabled for a VIN input.
• Filter configuration: the sinc5 + sinc1 filter is selected and the maximum output data rate of 31.25 kSPS is selected.
• ADC mode: continuous conversion mode and the internal oscillator are enabled. The internal reference is disabled.
• Interface mode: CRC and the data and status output are disabled.
• GPIO configuration: open wire detection is disabled.
Note that only a few of the register setting options are shown. This list is only an example. For full register information, see
the Register Details section. Figure 35 shows an overview of the suggested flow for changing the ADC configuration, divided into the following three blocks:
• Channel configuration (see Box A in Figure 35)
• Setup configuration (see Box B in Figure 35)
• ADC mode and interface mode configuration (see Box C in Figure 35)





SPI의 MISO핀이 RDY라서 어떻게 읽나 했는데 상태 레지스터에서 RDY를 보면 된다.




CONTINUOUS CONVERSION MODE
Continuous conversion mode is the default power-up mode.
The AD4111 converts continuously, and the RDY bit in the
status register goes low each time a conversion is complete. If CS
is low, the RDY output also goes low when a conversion is
complete



SINGLE CONVERSION MODE
In single conversion mode, the AD4111 performs a single
conversion and is placed in standby mode after the conversion
is complete. The RDY output goes low to indicate the completion
of a conversion. When the data-word has been read from the
data register, the RDY output goes high. The data register can
be read several times, if required, even when the RDY output goes
high.
If several channels are enabled, the ADC automatically sequences
through the enabled channels and performs a conversion on
each channel. When the first conversion is started, the RDY
output goes high and remains high until a valid conversion is
available and CS is low. When the conversion is available, the
RDY output goes low. The ADC then selects the next channel and
begins a conversion. The user can read the present conversion
while the next conversion is being performed. When the next
conversion is complete, the data register is updated; therefore,
the user has a limited period in which to read the conversion.
When the ADC has performed a single conversion on each of
the selected channels, it returns to standby mode.
If the DATA_STAT bit in the interface mode register is set to 1, the
contents of the status register, along with the conversion, are
output each time the data register is read. The four LSBs of the
status register indicate the channel to which the conversion
corresponds.









[링크 : https://www.analog.com/media/en/technical-documentation/data-sheets/ad4111.pdf]