하드웨어/RAID2024. 4. 18. 17:21

MegaRAID SAS 92xx 시리즈에서는 되는데 smc2108에서도 되려나?

1.6.7 Drive Roaming
Drive roaming occurs when the drives are changed to different ports on the same controller. When the drives are
placed on different channels, the controller detects the RAID configuration from the configuration data on the drives.
Configuration data is saved in both the NVRAM on the RAID controller and on the drives attached to the controller.
This action maintains the integrity of the data on each drive, even if the drives have changed their physical device ID.
NOTE If you move a drive that is being rebuilt, the rebuild operation restarts;
it does not resume from the stopping point.
Follow these steps to use the drive roaming feature:
1. Turn off the power to the server and all drives, enclosures, and system components. Disconnect the power cords
from the system.
2. Open the host system by following the instructions in the host system technical documentation.
3. Move the drives to different positions on the backplane to change the targets.
4. Determine the SAS target requirements.
5. Perform a safety check.
a. Make sure that the drives are inserted correctly.
b. Close the cabinet of the host system.
6. Reconnect the power cords to the system.
7. Turn on the power to the system.
The controller then detects the RAID configuration from the configuration data on the drives

[링크 : https://docs.broadcom.com/doc/12353227]

 

메뉴얼 상에는 없고(혹시 용어가 다르려나?)

[링크 : https://www.supermicro.com/manuals/other/lsi_2108_2208_sas_megaraid_configuration_utility.pdf]

[링크 : https://docs.broadcom.com/doc/LSISAS2108]

'하드웨어 > RAID' 카테고리의 다른 글

raid - predicted fail count  (0) 2024.04.22
MSM 디스크 제거시엔 stop!  (0) 2024.04.19
SSD cahcecade 포기  (0) 2024.04.18
MSM device id?  (0) 2024.04.17
금단의 키워드(!) San Foreign Configuration  (0) 2024.04.17
Posted by 구차니